ÐÇ¿ÕÕæÈË(ÖйúÓÎ)¹Ù·½ÍøÕ¾

³¤É³ÐÇ¿ÕÕæÈËÌìÏ ¹Ù·½
189 0731 9910

ÁªÏµÎÒÃÇ

µç»°£º0731-84211110
0731-82511110
ÊÖ»ú£º189 0731 9910
ÓÊÏ䣺changsha@wo.cn
꿅᣼https://cswuyou.com.cn
µØÖ·£º³¤É³ÊÐÔÀÂ´Çø¶Å¾é·ҫ¿­»¨Ô°3¶°301ÊÒ ÔÚÏß×Éѯ

ÂÁºÏ½ð½ÅÊּܰ²×°Ê¹ÓÃ˵Ã÷Êé

ÂÁºÏ½ð½ÅÊּܰ²×°Ê¹ÓÃ˵Ã÷Êé

·¢²¼ÈÕÆÚ£º2024-10-08¡¡ä¯ÀÀ´ÎÊý£º754

ÂÁºÏ½ðËþ¼ÜÊÇÒ»ÖÖ×éºÏÐ͵ÄÒÆ¶¯Ê½ÐÂÐÍÂÁºÏ½ð½ÅÊּܣ¬¹ã·ºÊ¹ÓÃÔÚ¸÷ÖÖ½¨Öþ¹¤³ÌÖÐÊÒÄÚ¡¢ÍâµÄÊ©¹¤¡¢×°ÐÞ¼°¸÷Öָ߿Õ×÷Òµ£»Æä½á¹¹ÌصãÊÇ£º¶àÑùÁé»î×éºÏ£¬°²×°¼ò±ã¿ì½Ý£¬²úÆ·ÒÆ¶¯·½±ã£¬ÐÔÄܰ²È«¿É¿¿¡£ÂÁºÏ½ðËþ¼ÜÊÇÔÚ½¨ÖþºÍ×°ÐÞÁìÓòÖеÄÒ»ÖÖÐÂÐͽÅÊÖ¼Üϵͳ£¬Æä¶àÑùÁé»îµÄ×éºÏģʽ£¬ÄܸüÈÝÒ×Âú×㹤³ÌµÄÊ©¹¤×÷ÒµÒªÇó¡£

111_¸±±¾.png

ÂÁºÏ½ðËþ¼Ü°²×°Ê¹ÓÃÖ¸ÄÏ

Aluminium Tower Assembly and Use Instruction

 

±¾ÊÖ²áΪÓû§ÌṩÂÁËþ¼ÜµÄ°²×°·½·¨£¬ÔÚ´î¼ÜºÍʹÓÃǰÓû§±ØÐëÏêϸÔĶÁ±¾ÊÖ²áµÄÄÚÈÝ£¬È罫ÂÁËþ¼Ü½»¸øµÚÈý·½Ê¹Ó㬱ØÐë¸´ÖÆÒ»·Ý±¾ÊֲḽËÍ£¬ÒÔ±£Ö¤Óû§ÊìÖª²¢°²È«Ê¹Óá£Èç¹ûÐèÒª¸ü¼ÓÏêϸµÄÐÅÏ¢»òÕß°²×°Ê¹ÓÃÖ¸ÄÏÓв»Çå³þµÄµØ·½,ÇëÁªÏµ³§¼Ò£¨¼û1.3£©¡£

  Í¬Ê±»¹ÒªÖ¸³ö£¬±¾ÊÖ²áµÄ½ÌѧÄÚÈݺÍʹÓò»ÊÇÏÈǰµÄЭÒ飬³Ðŵ»ò¾ßÓз¨ÂÉÔ¼ÊøÁ¦µÄ¹ØÏµµÄÒ»²¿·Ö¡£²úÉúµÄËùÓÐÒåÎñµÄÓйØÏúÊÛºÏͬ£¬ÆäÖл¹°üº¬Á˱£Ö¤ÍêÕûºÍΨһÓÐЧµÄÌõ¼þ£¨Ò²Çë²Î¼ûµÚ1.5½Ú£©¡£

±¾°²×°Ê¹ÓÃÖ¸Äϲ»¾ßÓз¨ÂÉЧÁ¦ºÍºÏͬ¸½¼þ³Ðŵ¡£

This user guide provides you step by step instruction to ensure your system is assembled easily and safely. Please read this user guide carefully before assembly adjusting and using. Any person using this tower should have a copy of this guide. If you need further information or, in the case of special requirements not adequately described in this assembly and use Instruction, please contact the manufacturer (see Section 1.3).

We also would like to point out that the content of this assembly and use instruction are not part of an earlier agreement, promise or a legally binding relation. All obligations arise from the pertinent sales contract, which also contains the complete and only valid conditions of warranty (also see Section 1.5). These contractual warranty conditions are neither expanded nor restricted by this assembly and use instructions.

1.¸ÅÊö General

1.1²úÆ·¸ÅÊö Description

Aluminum mobile towers are light-weight scaffold towers. It can be used in building and construction industry for both indoor and outdoor use and is a solution where a stable and secure platform is required. Furthermore it is ideal for maintenance and installation work or short-term access and the highly versatile tower provide a strong working platform for a variety of heights.

 

1.2 ʹÓÃ˵Ã÷ Introduction

Ö¸ÄÏÉÏÏà¹ØµÄ°²È«Ö¸Ê¾ÊÊÓÃÓÚ±¾ÎļþµÄÒÆ¶¯Ëþ¼Ü£¬Ê¹ÓÃÕß±ØÐë×öµ½Èçϼ¸µã£º

(1) È·±£×ñÊØ±¾µØ¡¢ÇøÓòºÍ¹ú¼ÒµÄÏà¹Ø¹æ¶¨¡£

(2) ×ñÊØ±¾Ö¸ÄÏÖеݲȫ²Ù×÷¹æ¶¨¡£

(3) È·±£¸öÈËÔÚʹÓùý³ÌÖÐÀí½â¸ÃÖ¸ÄÏ£¬Í¬Ê±Òª×ñÊØ¸÷·½ÃæµÄÄÚÈÝ¡£

The safety notes, rules and regulations in this assembly and use instruction related to the operation of standard mobile scaffold towers apply to the mobile scaffold towers in this documentation.

It is the responsibility of the operator to:

(1) Ensure that local, regional and national regulations are observed,

(2) Observe the rules (legislation, regulations, guidelines, etc.) in this assembly and use instruction for safe handling,

(3) Ensure that the assembly and use instruction is made available to personnel and that the information, notes, precautions and safety rules are observed in all aspects.

 

1.3 ±£Ö¤ Warranty

²úÆ·ÖÊÁ¿±£Ö¤·¶Î§ºÍÆÚÏÞÔÚ³§¼ÒÏà¶ÔÓ¦µÄÏúÊۺͳö»õÖбêÃ÷¡£

Èô²úÆ·ÔÚÏÂÊöÇé¿öÖб»ÆÆ»µµÄ£¬²»ÄÜÌṩÖÊÁ¿±£Ö¤£º

(1)ûÓа´ÕÕʹÓÃÖ¸ÄϲÙ×÷¡£

(2)¹¤×÷ÈËÔ±²»¹»×ʸñ¡£

(3)ÓÃÁËÆäËûÅä¼þ»òÕß²»ºÏ¸ñÅä¼þÌæ»»¡£

ʹÓÃÕß±ØÐë×¢Ò⣺

(1)Òª×ñÊØÊ¹ÓõݲȫÌõ¿î¡£

(2)È·ÈÏËþ¼ÜÊÇ·ñͨ¹ý²âÊÔÈÏÖ¤£¬°²×°ºÍʹÓÃÊÇ·ñ·ûºÏÒªÇó¡£

(3)×ñÊØºÏºõºÏͬµÄ²Ù×÷ָʾ¡£

The scope and period of warranty are stated in the sales and delivery conditions of the manufacturer.

The following applies beyond the scope of the sales and warranty conditions. No warranty shall be given for damage to the delivered standard mobile scaffold towers which may be due to one or more of the following reasons:

? Ignorance or non observance of this assembly and use instruction.

? Unqualified operating personnel.

? use of non-original replacement parts.

The operator/owner must ensure that

? the safety rules in Section 2 are observed,

? any applications for which the scaffold tower was not approved as well as an incorrect assembly and unauthorized use are excluded, and

? that an approved utilization is ensured and the standard mobile scaffold towers are used in accordance with the contractually agreed operating instructions.

 

2.°²È«Ìõ¿î Safety rules

2.1 °²È«ÐëÖª£ºsafety notes

 (1)ÂÁºÏ½ðËþ¼ÜµÄ°²×°ÖÁÉÙÓÐ2Ãû¼¼ÊõÈËÔ±ÏÖ³¡´î½¨£¬²¢È·±£Ê¹ÓÃÕýÈ·µÄ°²×°·½·¨¡£

The aluminium tower should be erected by at least 2 competent persons and ensure that the correct erection procedure is used.

 (2)¼ìÑé´î½¨Ëþ¼ÜµÄµØÃæÊÇ·ñÄܳÐÔØËþ¼ÜËùÐèµÄ×î´ó³ÐÔØÁ¦¡£

  Check if the ground on which the mobile access tower is to be assembled and moved is level, even and capable for supporting the tower.

(3)´î½¨Ëþ¼Ü֮ǰ¼ì²éËùÓÐÁ㲿¼þ£¬È·±£ËùÓÐÁ㲿¼þ¶¼ºÏ¸ñ£»Ëþ¼Ü°²×°ÍêºóÒªÓÃˮƽÒDzâÊÔËþ¼ÜÊÇ·ñ´¹Ö±£¬·½¿ÉʹÓá£

 Check if you have the correct equipment and if it is in working condition before you assemble the tower. After assembly, use a spirit level to check whether the tower is upright or not.

 (4)ÿ¿é̤°åµÄ×î´ó³ÐÔØÁ¦Îª272 kg¡£Ã¿¿é¹¤×÷ƽ̨×î´ó³ÐÔØÁ¦Îª200¹«½ïÿƽ·½Ãס£Æ½Ì¨×î´óˮƽºáÏòÁ¦Îª300Å£¶Ù¡£

   The maximum working load is 272kg per platform unit. The maximum capacity of the working platform for an evenly distributed load is 2.0 kN/m2 (according to EN 1004:2004 ¨C Load class 3). The maximum horizontal force at platform is 300N.

 (5)Ôö¼Ó¸ß¶ÈµÄ̤°åƽ̨ÔÚûÓÐ×°ÅäºÃÂÁ¼Ü£¨»ò»¤À¸£©µÄÇé¿öϲ»µÃʹÓ㻴»ò²ð³ýËþ¼Ü¹ý³ÌÖУ¬ÈκÎÁÙʱ̤°åµÄʹÓö¼Ó¦±»¿´×÷Êǹ¤×÷ƽ̨£¬²¢´øÓиßÓÚÆ½Ì¨0.5m»ò1mµÄ»¤À¸¡£

 Never work on, build or dismantle the tower from an unguarded platform. During erection or dismantling, every use of temporary platform should be considered as a working platform which must be consist of guardrails 0.5m or 1m above.

 (6)Ëþ¼Ü²ð³ý˳ÐòÓë´î½¨Ë³ÐòÏà·´¡£

The dismantling sequence is the reverse order of the erection process.

 (7) ÂÁËþ¼Ü´î½¨Ç°ÐèÓг§¼Òרҵ¼¼ÊõÈËÔ±½øÐÐÏÖ³¡²âÁ¿³ö¾ßÉè¼ÆÍ¼Ö½²¢½øÐÐÊÜÁ¦·ÖÎö¼ÆË㣬´ïµ½°²È«ÒªÇóºó·½¿É½øÐÐÏÖ³¡´î½¨£¬È糬¹ýÏà¹Ø¹æ¶¨Ðè×Éѯר¼Ò£¬²ÉÈ¡ÏàÓ¦µÄ·À»¤´ëÊ©¡£

Aluminum tower before build, need to have factory professional and technical personnel on-site measurement issue the design drawings and stress analysis calculation, to rear can conduct site set up safety requirements £¬Such as beyond rules should be consulting experts, take the corresponding protective measures ¡£

 (8)ËøºÃ½ÅÂÖ,½öÔÚÒÆ¶¯Ëþ¼Üʱ²Å¿ªËø¡£

Lock all castors by pushing down the brake levers. The brake levers may only be released for moving the mobile scaffold tower.

 (9)ÔÚ°²×°£¬²ðж£¬Òƶ¯ºÍ°²È«¹¤×÷ÆÚ¼ä£¬È·±£²»´æÔÚÈκÎÕϰ­£¡ÔÚ¼ÜÉ裬²ðж£¬Òƶ¯ºÍ°²È«¹¤×÷ÆÚ¼ä£¬Ìá·À·ç¿ö£¡

Make sure there is no any obstruction during erection, dismantling, moving and safe working! Beware of wind conditions during erection, dismantling, moving and safe working!

 (10)ËùÓÐËþ¼ÜʹÓÃʱҪÓб߱£»¤ÎÈçÌ߽Ű塢ΧÀ¸µÈ¡£

All mobile scaffold towers only are used with complete side protection, i.e. toe boards, principal guardrail and intermediate side protection.

 (11)Ëþ¼ÜÔÚÊÒÍâʹÓÃʱ£¬·çËÙÈô³¬¹ý6¼¶£¬½«Ëþ¼ÜÒÆ½øÑڱ䦻òÔö¼Ó¹Ì¶¨£¨Èç¼Ó꣩·ÀÖ¹Çãµ¹¡£

When using the mobile scaffold tower outside or in open buildings at a wind force over 6 (on the Beaufort scale), move it to an area sheltered from the wind or secure it against tipping over with other suitable means (e.g. anchors).

 (12)²»Òª½«×Ô¼º¿¿ÔÚ²à±ß»¤À¸ÉÏ¡£

Do not lean yourself against the side guards when working.

 (13)²»ÒªÔÚÆ½Ì¨Ì¤°åÉÏÌø¶¯¡£Do not jump on the platform.

 (14)²»Òª²úÉúˮƽÀ­Á¦£¬ÀýÈçÔÚ¿¿½ü½¨ÖþÎ﹤×÷ʱ£¬Ëþ¼Ü¶¥²¿²úÉúˮƽÁ¦¶øÇãµ¹¡£

Do not create horizontal loads, for example, by working on close constructions, which could cause the mobile scaffold tower to tilt over.

 (15)ÔÚÖпÕ¡¢Î´·â¶¥»ò±ß½ÇµÄ½¨ÖþÎïÉÏʹÓÃËþ¼Üʱ£¬×¢Ò⿼ÂÇ·çÁ¦µÄÓ°Ïì¡£

When using the mobile scaffold tower in through-buildings, on uncovered buildings or on the corners of buildings, pay particular attention to the wind conditions to prevent the mobile scaffold tower from tilting over.

 (16)ʹÓÃËþ¼Ü֮ǰҪ¼ì²éËþ¼ÜµÄ´¹Ö±¶È¼°Òò»·¾³ÒýÆðµÄ°²È«±ä»¯£¬²¢ÐÞ¸ÄÍêÉÆ(µ÷½Ú½ÅÂÖʹÕû¸öËþ¼Üƽºâ´¹Ö±)¡£

Before using the mobile scaffold tower, check the perpendicularity of the scaffold tower, correcting it if necessary(adjust the caster). Furthermore, inspect the mobile scaffold tower for proper and complete assembly. Also check there are no environmental changes influencing the safety of the mobile scaffold tower.

 (17)×¢ÒâÖÜΧ»·¾³µÄµçÁ¦ÒòËØÓ°Ï죬Èç¸ßѹµçµÈ¡£

Identify any electrical risks in the work area, such as overhead lines or other exposed electrical equipment.

 (18)ÌØ±ð»òÕßרÓõÄËþ¼Ü°²×°ÇëÁªÏµ¹©Ó¦ÉÌ»ò×Éѯר¼ÒÒâ¼û¡£

For special or unusual applications, contact your supplier for further technical data sheets and expert advice.

 (19)Ëþ¼ÜÉϲ»Äܸ½ÓÐÉý½µÉ豸¡£

Do not attach hoists or similar devices to the mobile scaffold tower to lift loads.

 (20)¹¤×÷ÈËÔ±Ö»ÄÜ´ÓËþ¼ÜÖÐÌÝ×ÓµÄÄÚ²àÉÏÂ䣬²»µÃ´ÓËþ¼ÜµÄÍâ²àÉÏÂä¡£

Always climb onto the tower from inside.

 (21)²»ÒªÓÃ̤°åÀ´Á¬½ÓËþ¼ÜºÍ½¨ÖþÎËþ¼Ü²»ÄÜ×÷Ϊ¥ÌÝÀ´ÅÊµÇÆäËû½¨Öþ¡£

Do not connect mobile scaffold towers to buil-dings with planks, etc. The mobile scaffold

tower can not be used as a staircase for ascen-ding to other constructions.

 (22)²»ÄÜÓÃÌÝ¡¢ºÐ»òÆäËû×°±¸ÔÚËþ¼ÜÉÏ×÷ΪÉý¸ß¹¤×÷̨Ó㻹¤¾ß¼°²ÄÁϵÈÖ»ÄÜÓÃÊÖÄ㬲»ÄÜ´ÓµØÃæÍùËþ¼ÜÉÏÅ×£¬Òª¿¼ÂÇÏàÓ¦µÄÖØÁ¿¶ÔËþ¼ÜµÄÓ°Ïì¡£

Do not use ladders, boxes or other devices to increase the height of the platform. Tools and  materials may only be handed up. Always taking the weight of the tools and materials into con-sideration so as not to overload the working plat-form. Only re-lease the load when the recipient of the load is secure in hands.

2.2 ÌØÊⰲȫÌõ¿î Special safety rules

a) °²×° Erection 

.¹¤×÷ÈËÔ±ÔÚ°²×°/²ðжËþ¼Üʱһ¶¨Òª°ó°²È«´ø¡£

Under no circumstances safety harnesses shall be attached to the towers during erecting or dismantling.

. ¼ì²éËùÓÐÅä¼þÊÇ·ñÆëÈ«¡¢ºÏ¸ñ¡£

Check that all components are on site and that they work correctly.

. ¼ì²éµØÃæÇé¿öÊÇ·ñÄÜ×ã¹»³ÐÊÜËþ¼Ü°²×°Ê¹Óá£

Check that the ground on which the mobile access tower will be assembled and moved is fairly level, even and capable of supporting the tower.

 

.µ÷½Ú½ÅÂÖÖ§¼ÜʹËþ¼Üƽºâ¡£Adjustable legs should only be used for leveling.

b)Éý½µÉ豸 Lifting equipment 

. Ëþ²¿·ÖӦʹÓÃÀι̿ɿ¿µÄÌáÉý²ÄÁÏ£¨ÈçÉþ£©£¬Ê¹Óÿɿ¿µÄ½á£¬ÒÔÈ·±£°²È«½ô¹Ì¡£

. Tower components should be firmly secured by a reliable lifting material (e.g. rope), employing a reliable knot, to ensure safe fastening.

c) Ìá¸ßºÍ½µµÍÎï¼þ£¬¹¤¾ßºÍ/»ò²ÄÁÏÓ¦ÀûÓÃÉþÔÚËþ»ùÄÚ²¿½øÐС£È·±£Ö§³Ö̤°åºÍËþ½á¹¹µÄ°²È«²Ù×÷¸ººÉ²»±»³¬¹ý¡£

 Raising and lowering components, tools, and/or materials by rope should be conducted within the tower base. Ensure that the safe working load of the supporting decks and the tower structure is not exceeded.

d) Ð±³Å/¸ºÖØ   Stabilizers/ Ballast 

. б³ÅʼÖÕ°²×°ÔÚÖ¸¶¨Î»Öá£

. Stabilizers should always be fitted when specified.

.¸ºÖØÓÃÓÚÎȶ¨Ëþ¼Ü£¬·ÀÖ¹Ëþ¼ÜÇ㸲¡£Ëü±ØÐëÊǹÌÌåÎïÖÊ£¨¼´²»ÊÇË®»òËÉɢɰ£©£¬¶ø²»Ó¦¶¨Î»ÓÚÖØÔØ¸ö±ðÍÈ¡£¸ºÖØÓ¦ÉèÓзÀÒâÍâж³ý£¬²¢Ö§³ÖÒÔ×îµÍµÄµ×²¿¿ò¼ÜÌݼ¶°²×°¡£

. Ballast is used at the base to stabilize towers against overturning. It must be of solid materials (i.e. not water or loose sand) and should not be positioned to overload individual legs. Ballast should be secured against accidental removal where practicable and should be supported on the lowest rung of the bottom frame.

e) ʱ³£ÁôÒâ²¢×ñÊØµ±µØµÄÓйصط½µ±¾Ö¹«²¼µÄ¹æ¶¨¡£

e) Always observe and comply with the concerning local regulation published by the local authorities .

2.3 ÒÆ¶¯°²È« Movement safety 

 £¨1£©Òƶ¯Ç°Ïȼì²éÔÚÒÆ¶¯µÄ¹ý³ÌÖУ¬µØÃæÓÐÎÞÕϰ­ÎÈ罨ÖþÎݶ¥½á¹¹¡¢µçÀµçÏߵȸ߿ÕÕϰ­Îï¡£

Before moving the tower, beware of soft or uneven ground, rains or pot holes and overhead obstructions, especially power cables. The ground shall be level, hard and generally level enough.

 £¨2£©Ëþ¼ÜµÄÒÆ¶¯Ö»ÄÜÒÀÕÕ³ÌÐòÈ˹¤Òƶ¯£¬¾ö²»¿ÉÒÔ²ÉÓûúеµÄ·½Ê½Òƶ¯£¬ÈçÍϳµ»ò²ù³µÒƶ¯£»Ëþ¼ÜÒÆ¶¯ºóÂíÉÏ֯ɲ²¢¼ì²éËþ¼Ü´¹Ö±Îȶ¨¡£

The tower should only be moved by manual effort! Do not move the mobile scaffold tower with vehicles (e.g. lift trucks). Do not lift, pull or push the mobile scaffold tower with a lift truck. Immediately after moving, brake all castors by pushing down the brake lever, then check whether the tower is upright and stable or not.

 £¨3£©Òƶ¯Ëþ¼Üʱ²»µÃÓÐÈË»òÆäËû¶«Î÷ÎïÌåÖÍÁôÔṲ́°åÉÏ¡£

No personnel or material is allowed on the tower during movement.

 £¨4£©ÔڸߵͲ»Æ½µÄµØÃæÒƶ¯Ëþ¼Üʱһ¶¨ÒªÐ¡ÐÄ£¬Òƶ¯Ç°ÒªÇå³ýµØÃæÉϸß12mmµÄÕϰ­ÎÇÒ²»ÄÜÔÚÓÐÆÂ¶ÈµÄµØÃæÉÏÒÆ¶¯¡¢Ê¹Óá£

Caution should be exercised when moving a tower over rough, uneven or sloping ground, clear ground obstruction which is over 12mm above the ground 

 £¨5£©Òƶ¯Ê±Òª×¢Òâ±£Ö¤Ëþ¼ÜµÄÎȶ¨ºÍ°²È«£¬Ö§³ÅÈý½Çб³ÅÒªÓëµØÃæ±£³Ö12mm¡ÜH¡Ü20mmµÄ¾àÀ룬ÒÔÆðµ½·ö³ÖµÄ×÷Óá£

Be aware of tower is stable and secure during movement. Stabilizers should keep the distance 12mm¡ÜH¡Ü20mm to the ground to support the tower.

 £¨6£©Òƶ¯Ëþ¼Üʱ½ÅÂÖ²»µÃÖÆ¶¯£¬È·±£½ÅÂÖÄÜת¶¯×ÔÈç¡£

Ensure the brakes are unapplied during movement in order that the caster can be rolling with no break.

 £¨7£©¼ì²éÏÖ³¡»·¾³£¬ÒÔÈ·±£Ã»ÓÐÓ°ÏìÂÁºÏ½ðËþ¼ÜÒÆ¶¯µÄÆäËûÒòËØ´æÔÚ¡£

Inspect the circumstance, ensure there is no factor which will effect the movement of the tower.

 £¨8£©²»ÄÜÒÔÐгµËÙ¶ÈÒÆ¶¯Ëþ¼Ü£¬Ö»ÒªÂýÂýÒÆ¶¯¡£

Do not roll the tower at running speed. Just walk slowly.

 £¨9£©Í¨¹ýµ÷Õû½ÅÂÖÉϵĿɵ÷½ÅÈ·±£Òƶ¯Ëþ¼ÜµÄˮƽºÍ´¹Ö±¡£

Level and plumb the mobile scaffold tower by adjusting the base jacks on the castors.

 £¨10£©Çë¼Çס£¬Ëþ¼ÜÒÆ¶¯ºó£¬ËøºÃËùÓеĽÅÂֺͼÓÇ¿ÍâÖ§³ÅÓëµØÃæµÄ½Ó´¥¡£

Remember to lock all brakes and tighten the stabilizers against the ground after the tower is relocated.

 £¨11£©Ê¼ÖÕ×ñÊØ¼°ÂÄÐÐÓйصط½Óɵط½µ±¾Ö¹«²¼µÄ¹æ¶¨¡£

Always observe and comply with the concerning local regulation published by the local authorities.

 

2.4 ÂÁºÏ½ðËþ¼ÜʹÓÃÖÐ×¢Òâ·çÁ¦ÒòËØµÄÓ°Ïì  Attention to the wind  effect

ÂÁºÏ½ðËþ¼ÜÔڸ߿ÕÖÐʹÓ㬷çµÄÒòËØÆðµ½ºÜ´óµÄ×÷Óã¬ÔÚÊʵ±µÄ·çÁ¦»·¾³Ï£¬×¢ÒâÓб£»¤µÄÌõ¼þϽøÐа²È«¹¤×÷£¬¶ø·çÁ¦½Ï´óʱºÍûÓÐÓÐЧµÄ¹Ì¶¨ºÍÎȶ¨µÄ±£»¤Ìõ¼þÏ£¬·çµÄÒòËØ³ÉΪÂÁËþ¼Ü×îΣÏÕµÄÌõ¼þÖ®Ò»£¬±ØÐ뿼ÂDz¢¹Ø×¢·çµÄÒòËØ£ºÔÚ·çËÙ>7.7mÿÃëʱ,Í£Ö¹Ëþ¼Ü¹¤×÷;Èç¹û·çËÙ´ïµ½11.3mÿÃëʱ,½«Ëþ¼Ü°óÔÚ½¨ÖþÎïÉÏ;Èç´ïµ½18mÿÃëʱ,Ðè²ð³ýËþ¼Ü¡£

During use, wind takes a great part in effect. In suitable wind environment, the tower can be safety used under protection. When the tower posited in high wind and without any effective protection, wind is one of the most dangerous factor and should be awared. We recommend to pause work on the tower in wind speeds over 7.7 metres per second (17m.p.h.). If the wind becomes a strong breeze, expected to reach 11.3 metres per second (25 m.p.h.), tie the tower to a rigid structure. If the wind is likely to reach storm force, over 18 metres per second (40 m.p.h.), the tower should be dismantled.

 

ÆÑ¸£·ç¼¶¶È±ê

·çËÙÃèÊö

¼¶Êý

ÿmphµÄËÙ¶È

Ó°Ïì

±£»¤´ëÊ©

ºÍ·ç

4

21-29

·ç¡¢Ê÷Ò¶¡¢Ö½¿É´µÆð

°²È«¹¤×÷

΢·ç

5

30-39

СÊ÷°Ú

Í£Ö¹¹¤×÷

¼²·ç

6

40-50

СÊ÷Ö¦Ò¡°Ú¡¢µç»°Ïß·¢³öÉùÒôµÈ

²ÉÈ¡´ëÊ©±£»¤Ëþ¼Ü

±©·ç

8

63-74

СÊ÷Ö¦ÕÛ¶Ï¡¢ÄÑÐÐ

²ð³ýËþ¼Ü


2.5
ά»¤  Maintenance and Storage

ËùÓÐÁ㲿¼þÓ¦µ±¶¨ÆÚ¼ì²é£¬ÒÔ±êʶË𻵣¬ÌرðÊǺ¸½Ó¡¢¶ªÊ§»òÕ߯ÆÁѵIJ¿¼þÓ¦µ±Ìæ»»£¬¶øÇÒÈκÎȱ¿Ú³¬¹ý5mmµÄ¹Ü¼þÓ¦µ±·Åµ½Ò»±ßÒÔ½øÐÐÉú²úάÐÞ£»¿Éµ÷Ö§³ÅÍÈÂÝÎÆÓ¦µ±Çå½à¸É¾»£¬²¢¼ÓÈó»¬ÓÍÒÔ±£³ÖÔË×÷˳³©¡£²¿¼þ±ØÐë´æ·ÅÔÚ°²È«µÄµØ·½£¬ÔÚ´æ·ÅÆÚ¼ä£¬×¢Òâ°ü×°ºÃ²¿¼þÒÔ·ÀÊÜÌìÆøÓ°Ï죬×îºÃÊÇÆ½·ÅÔÚµØÉÏ¡£ÔÚ¹¤µØÊ¹ÓÃÍê×ªÒÆµ½´æ·ÅµÄµØ·½£¬±ØÐë¼ì²éÊÇ·ñ»áÓÐËɶ¯£¬ÊÜÍâÁ¦Ó°Ïì¶øÇãµ¹µÄ¿ÉÄÜÐÔ¡£ÔÚ²Ù×÷ʱ£¬²»ÄÜËæÊÖÂÒÈÓ²¿¼þ¶øÔì³ÉË𻵣¬±ØÐëÇáÄÃÇá·Å¡£

 (1)All components and their parts should be regularly inspected to identify damage.

 (2)Any damaged parts or components found shall be replaced.

 (3) Repair of scaffold material is only allowed after consultation with the manufacturer or supplier.

 (4) Lubricate all moving parts with a standard commercial oil.

 (5) The scaffold tower components must be stored in such a way that they are not damaged. During storage, the scaffold tower components must be protected against the effects of weather. Store them lying down if it is possible.

During transport to or from the place of storage, the scaffold tower components must be secured against sliding, impacting and falling off. Do not throw scaffold tower components during handling.

 

3.¼¼ÊõÐÔÄܼ°¼¼Êõ²ÎÊýTechnical data

 (1) ¶¥²ãµÄ¹¤×÷ƽ̨×î´ó³ÐÔØ200Kg/m2¡£

The safe working load on the top platform is 2kN/m2.(EN 1004 class 3 )

 (2) ¸ß¶ÈµÄ²»Í¬×éºÏÐÎʽ£ºÊÒÄÚ±ê×¼¼ÜÔÊÐí×î¸ß´î½¨¸ß¶ÈÔÚ12Ã×ÄÚ£¬»§Íâ±ê×¼¼Ü×î¸ß´î½¨¸ß¶ÈΪ8Ã×ÄÚ¡£ÈçÊÇÌØÊâÉè¼ÆÇëÁªÏµ³§¼Ò»òרҵ¹¤³ÌÈËÔ±ÌṩÏà¹Ø½â¾ö·½°¸£¬ÒÔ±£Ö¤°²È«·¶Î§ÄÚʹÓá£

Different kinds of combination of height: the maximum platform height for indoor use is 12 meter, for outdoor use it is 8 meter. If it is special requirement,please refer to

manufacturer or qualify Engineer for professional solutions,which guarantee for safety usage.

¡ï¡ï¾¯¸æ£¡£ºÓÀÔ¶¶¼²»ÄÜÔÚûÓл¤À¸µÄƽ̨ÉϹ¤×÷»òÕߴ/²ð³ýËþ¼Ü£»Ã¿´Î´Ó¿ª´°Ì¤°åÅÀÉÏËþ¼Üºó¶¼ÒªÂíÉϹغô°°å¡£

¡ï¡ïCaution!:Working on platform without guard-rail is prohibited. Remember to always close trapdoor immediately  after climbing through.

²ð³ý  DISMANTLING

×¢Òâ   ÒÆ¶¯½ÅÊÖ¼ÜËþµÄ²ð³ýÊǰ´ÕÕ°²×°µÄÏ෴˳Ðò½øÐС£

NOTE   The dismantling of the mobile scaffold tower is in the reverse order of assembly.

/ 

189 0731 9910
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿